Diese Seite ist nicht vollständig übersetzt. Klicken Sie auf die Schaltfläche Übersetzen, um die neueste übersetzte Version zu laden.

visibility Similar

code Related

Radiography and radio-therapeutics (1917) (14571426007)

description

Zusammenfassung

Identifier: radiographyradio01knox (find matches)

Title: Radiography and radio-therapeutics

Year: 1917 (1910s)

Authors: Knox, Robert, 1868-1928

Subjects: Radiography Radiotherapy

Publisher: New York : Macmillan

Contributing Library: University of California Libraries

Digitizing Sponsor: Internet Archive

Text Appearing Before Image:

ble, and make the exposure. All exposures should, if possible, be made at a uniform distance of, say, 60 cm. between the anti-cathode and the plate. ^ Technique with the Coolidge Tube, in the American Journal of Roentgenology,May 1916. ESTIMATION OF THE EXPOSURE 135 Dr.Kuegle gives the following table for the three kinds of plates he uses: Thicknessof Part. Cm.1234567891011121314151617181920 Paragon Plate. Time (Sec.) u 23 4567891012131416171820222426 Seed Plate. Cramer Plate. Time (Sec.) 2 3 4 5 6 7 8 9 10 11 12 15 16 17 19 21 23 25 27 29 Time (Sec.) 2i 4 5 6 8 9 10 11 12 14 16 17 19 21 22 23 25 27 29 31 Screen. 2 2\ 3 H 4 5 5i 7 910111213 Gregory Cole gives the following data for exposure mth a Coolidge tube Part of Body. Hand, soft parts .Hand, bone .Foot, soft tissues, lateralFoot, bone, lateralKnee, soft parts .Knee, bone and soft tissueKnee, bone only .Shoulder, soft tissues Shoulder, bone Hip, bone Kidney . Spine, bone, detail Head, lateral . Head, A.P. . Lungs Stomach (Screen)

Text Appearing After Image:

Exposure TablesComparison of Different Radiometers Benoist .Benoist-WalterWalter .WehneltBauer . 2 1 2-3 1-81 2i2 3-43-3 2 3 4 5 6 7 3 4 4i 5 5^ 4-5 5-6 6 6-7 7 4-9 6-5 7-2 8 9 3 4 5 6 7 6 7-810-5 9 10 13 15 9 10 TI«> IntensUy of the X-rays varies wUh the Distame between the Mi-cathode and the Plate.-Ti^e intensity of the X-rays is m mverse proportion 136 RADIOGEAPHY to the square of the distance. If we have to expose for a certain object3 seconds, with a distance of 10 inches between the anti-cathode and theplate, the time of exposure required with 10, 12, 16, 20, 25, 30, 40, 50,60, 80 inches will be 3, 4-32, 7-68, 12, 18-75, 27, 48, 75, 108, 192 seconds ;or, expressed in other figures : Distance 10 14-1 17-3 20 22-4 24-5 26-4 28-3 30 cm.Exposure 10 20 30 40 50 60 70 80 90 M.A. seconds. The distances usually chosen are : For teeth, toes, fingers, or hands . . 10 to 12 inches. Arms, neck, leg, or foot . . . . 12 „ 15 „ Nose, head, shoulder, knee . . . 20 „ 22 „ Chest, kidn

label_outline

Tags

Radiographie und Strahlentherapie 1917 Röntgenstrahlen Buchillustrationen Medizin Röntgen Geschichte der Technologie Röntgen Bilder aus dem Internetarchiv
date_range

Datum

1917
create

Quelle

University of California
link

Link

http://commons.wikimedia.org/
copyright

Copyright-info

public domain

label_outline Explore Radiography And Radio Therapeutics 1917

Themen

Radiographie und Strahlentherapie 1917 Röntgenstrahlen Buchillustrationen Medizin Röntgen Geschichte der Technologie Röntgen Bilder aus dem Internetarchiv