visibility Similar

code Related

Radiography, x-ray therapeutics and radium therapy (1915) (14755177844)

description

Summary

Identifier: radiographyxrayt00knoxuoft (find matches)

Title: Radiography, x-ray therapeutics and radium therapy

Year: 1915 (1910s)

Authors: Knox, Robert, 1868-1928

Subjects: Radiography Radiotherapy X-rays

Publisher: London : A. & C. Black

Contributing Library: Gerstein - University of Toronto

Digitizing Sponsor: MSN

Text Appearing Before Image:

Fig. 50.—Oscilloscope tube in action.(Schall.) «, The appearance of a tube with the currentpassing in the right direction with a traceof reverse current. h. The appearance with the current passingin both directions in almost equal pro-portions. 54 KADIOGKAPHY Secondary Radiations, Cause, and Methods of Suppression.— Secondary rays are produced by the reverse current. All those X-rayswhich do not emanate from the focus of the anti-cathode are called secondaryrays. They have the same penetrating power as the primary rays and areplentiful in hard tubes, but they project the outlines of the objects in otherdirections than the primary rays, and a loss of sharpness results. When they are present it is necessary to do something to preventdeterioration of the negafive. Secondary rays are also produced, or adiffusion of the primary rays takes place in the patients body. It is probable

Text Appearing After Image:

Fig. 51. LCBA ABCD -Diagrams showing the paths taken by priniarj beams and secondary rays. (Schall.) that both of these manifest themselves during a long exposure. Fig. 51shows the path taken by the primary beam, and the manner of projection ofsecondary rays upon the photographic plate. The X-rays, A A, emanating from the focus of the anti-cathode projecta shadow, B B, of the object, 0, on the plate. If there were no secondaryrays this shadow would be of uniform darkness from B to B, and the space,BCD, would be free from any shadow. But if any current discharges inthe WTong direction, the so-called secondary rays are generated on the glassof the tube. They are indicated by the dotted hues h h. Although weakerin intensity, they project shadows, and in another direction than the primaryrays will do; the shadows overlap, and the part between A B will not be so SUPPRESSION OF SECONDAEY RADIATIONS 55 dark as that between A A and the space between B C will not be as clear asthat between C D

label_outline

Tags

radiography x ray therapeutics and radium therapy 1915 book illustrations x ray medicine medical therapy images from internet archive canada
date_range

Date

1915
create

Source

University of Toronto
link

Link

http://commons.wikimedia.org/
copyright

Copyright info

public domain

label_outline Explore Radiography X Ray Therapeutics And Radium Therapy 1915

Topics

radiography x ray therapeutics and radium therapy 1915 book illustrations x ray medicine medical therapy images from internet archive canada