Diese Seite ist nicht vollständig übersetzt. Klicken Sie auf die Schaltfläche Übersetzen, um die neueste übersetzte Version zu laden.

visibility Similar

A U.S. Air Force crew chief with the 9th Expeditionary

Army Corps of Engineers fully engaged in Louisiana hurricane recovery efforts

SAN JUAN, Puerto Rico. – Jason Culbreth, a Generator

STS106-372-028 - STS-106 - Views of the Node 1 hatch to PMA2 taken during STS-106 mission

Report of the Electric Railway Test Commission to the president of the Louisiana Purchase Exposition (1906) (14572229367)

Carlos Luera, a sheet metal mechanic in the disassembly

CAPE CANAVERAL, Fla. -- House Of Representatives Democratic Leader Nancy Pelosi, from California's 8th District, is greeted by NASA Kennedy Space Center Director Robert Cabana. Pelosi is at Florida's space center to witness space shuttle Discovery make history as it lifts off on its final scheduled mission from Launch Pad 39A. While at the center, Pelosi attended a presentation in the Operations Support Building II and toured Orbiter Processing Facilities 1 and 2 where shuttles Atlantis and Endeavour are being prepared for their final missions respectively. Discovery and its six-member STS-133 crew will deliver the Permanent Multipurpose Module, packed with supplies and critical spare parts, as well as Robonaut 2, the dexterous humanoid astronaut helper, to the International Space Station. Discovery will make its 39th mission and is scheduled to be retired following STS-133. This will be the 133rd Space Shuttle Program mission and the 35th shuttle voyage to the space station. For more information on the STS-133 mission, visit www.nasa.gov/mission_pages/shuttle/shuttlemissions/sts133/. Photo credit: NASA/Jim Grossmann KSC-2011-1681

code Related

A manual of practical medical electricity - the Röntgen rays and Finsen light (1902) (14780564631)

description

Zusammenfassung

Identifier: manualofpractica00turn (find matches)

Title: A manual of practical medical electricity : the Röntgen rays and Finsen light

Year: 1902 (1900s)

Authors: Turner, Dawson

Subjects: X-Rays Electrophysiology Electrosurgery Electric Stimulation Therapy Electrotherapeutics X-rays Electrophysiology Electrosurgery

Publisher: New York : William Wood & Company

Contributing Library: Francis A. Countway Library of Medicine

Digitizing Sponsor: Open Knowledge Commons and Harvard Medical School

Text Appearing Before Image:

which shouldfrom time to time be passed through the tube, and by theresistance offered to the passage of the electricity. Atthe proper degree of exhaustion, that part of the wall ofthe tube which is opposite the free surface of the anodewill be bathed with a greenish-yellow phosphorescence, 21—2 324 A Manual of Practical Medical Electricity and the bluish-white Hght in the body of the tube willhave disappeared. The resistance of the tube to thepassage of the electricity at first diniinishes until itreaches a minimum, and then rapidly augments again.The pumping process should not be considered completeuntil the resistance has been brought up to about thatof a 3-inch alternative air spark gap. Much, however,depends upon the size of tube exhausted and upon itstemperature. A fluorescent screen can also be used to determine thepresence and amount of X radiatioiL It is prudent tocarry the exhaustion a little further than is necessary togive the best results while on the pump, because the

Text Appearing After Image:

Fig. 141.—Diagram of Watsons Penetrator Tube. vacuum is liable to be slightly impaired during the processof sealing. Good makers of tubes are Miieller of Hamburg andHirschmann of Berlin ; the gold medal of the RontgenSociety was awarded to the former, and I have had someof the latter for more than a year in fairly constant use.Cox, of 10, Cursitor Street, or Miller, of 93, Hatton Garden,can supply these tubes. A large tube has the advantage of containing a greaterresidual store of air, which can be drawn on when desiredby slightly warming the tube. With a small tube, thevacuum increases so rapidly with use that it soon becomesdifficult, on account of the resistance, to pass the dischargethrough it. The tube should be held in a tube-holder, and the RoNTGEN X Rays 325 electrodes connected with the secondary terminals of theinduction coil by fine copper wire. The platinum anodeof the tube must be attached to the positive terminal ofthe coil, and the concave kathode of the tube to thene

label_outline

Tags

ein Handbuch der praktischen medizinischen Elektrizität Buchillustrationen Medizin medizinische Illustrationen Krankengeschichte Geschichte der Technologie elektrische Energie Elektrizität Röntgen röntgen medizinische Therapie Elektrotherapeutika Bilder aus dem Internetarchiv Hamburg Deutschland
date_range

Datum

1902
create

Quelle

Open Knowledge Commons and Harvard Medical School
link

Link

http://commons.wikimedia.org/
copyright

Copyright-info

public domain

label_outline Explore A Manual Of Practical Medical Electricity

Themen

ein Handbuch der praktischen medizinischen Elektrizität Buchillustrationen Medizin medizinische Illustrationen Krankengeschichte Geschichte der Technologie elektrische Energie Elektrizität Röntgen röntgen medizinische Therapie Elektrotherapeutika Bilder aus dem Internetarchiv Hamburg Deutschland