visibility Similar

code Related

Röntgen rays and electro-therapeutics - with chapters on radium and phototherapy (1910) (14755100681)

description

Summary

Identifier: rntgenrayselectr00kass (find matches)

Title: Röntgen rays and electro-therapeutics : with chapters on radium and phototherapy

Year: 1910 (1910s)

Authors: Kassabian, Mihran Krikor, 1870-1910

Subjects: Electrotherapeutics X-rays Phototherapy Radiology Radiotherapy

Publisher: Philadelphia & London : J.B. Lippincott Company

Contributing Library: Francis A. Countway Library of Medicine

Digitizing Sponsor: Open Knowledge Commons and Harvard Medical School

Text Appearing Before Image:

ration or the degreeof hardness of the Eontgen light. In comparison with other dosimetric ^Archives of the Rontgen Ray, June, 1906, p. 17.^ Journal of Cutaneous Diseases, December, 1903.^Archives of the Rontgen Ray, June, 1906, p. 17. TECHNIC OF EONTGEN RAY THEEAPY. 435 metliods, tlie quantimetric method lias the advantage of greater exact-ness and the possibility of estimating small differences of dosage. Thismethod gives a permanent registered record. The disadvantage of thismethod is the difficulty which is encountered in comparing and distin-guishing the slight differences of tint on the scale. Careful developmentis necessary and always tedious. When massive doses are given thecolor will be darker and will be more difficult for making comparisonwith the scale. The degree of the sensitiveness of the emulsion of thepaper may frequently differ. TJie Xeic Eadiometer of Freutul.—Freunds method was used in 1904,and is based on the color changes occurring in a two per cent, solution of

Text Appearing After Image:

Fig. 221.—Kienbocks quaatimeter. pure iodoform in chloroform. This solution normally retains its colorunchanged for 48 hours, and is so very sensitive that a difference of tintmay be observed between two portions of the solution, one of which isexposed to the rays for three minutes, while the other portion is screenedfrom the action. Slight heat and light will alter the color of the solution,and, although this method is most accurate and sensitive, the solution istoo unstable for practical and clinical purposes. The iodoform (CHI3) is decomposed by the X-rays, with the libera-tion of free iodine, imparting a claret-color to the solution. Freundssolution shows a change of tint in six minutes, equal to that attained inten minutes by the use of Holzknechts pastilles. 436 ELECTEO-THEEAPEUTICS. Precipitation Test.—Schwartz,^ of Vienna, demonstrated a methodof measuring the strength of the Eontgen rays, based on the precipita-tion of calomel in a mixture of ammonium oxalate and corrosiv

label_outline

Tags

rontgen rays and electro therapeutics 1910 book illustrations medicine medical illustrations medical history x ray röntgen diseases electrotherapeutics images from internet archive austria
date_range

Date

1910
create

Source

Open Knowledge Commons and Harvard Medical School
link

Link

http://commons.wikimedia.org/
copyright

Copyright info

public domain

label_outline Explore Rontgen Rays And Electro Therapeutics 1910

Topics

rontgen rays and electro therapeutics 1910 book illustrations medicine medical illustrations medical history x ray röntgen diseases electrotherapeutics images from internet archive austria