visibility Similar

code Related

Röntgen rays and electro-therapeutics - with chapters on radium and phototherapy (1910) (14778011923)

description

Summary

Identifier: rntgenrayselectr00kass (find matches)

Title: Röntgen rays and electro-therapeutics : with chapters on radium and phototherapy

Year: 1910 (1910s)

Authors: Kassabian, Mihran Krikor, 1870-1910

Subjects: Electrotherapeutics X-rays Phototherapy Radiology Radiotherapy

Publisher: Philadelphia & London : J.B. Lippincott Company

Contributing Library: Francis A. Countway Library of Medicine

Digitizing Sponsor: Open Knowledge Commons and Harvard Medical School

Text Appearing Before Image:

let ray applications. I cannot, however, endorse such views.To me it does not seem plausible that any one machine can give all of thesevarious currents with equal degrees of satisfaction. For heavy work andto meet the exigencies of the Eontgenologist, I believe that specialapparatus adapted for each particular purpose is indispensable for theaccomplishment of the best possible results. B. Installation. It remains to give a brief resume of the arrangement and manage-ment of the different parts concerned in the production of a skiagraph.The first essential is to determine the nature of the current available. THE EONTGEN EAY APPAEATUS. 195 The coil cau be energized by an accumulator or by the continuous oralternating cm-rent from the street supply. In the latter instance thetransformer is necessary to reduce the enormous voltage. Some place thecoil upon the table ; my own preference is to rest it upon a shelf attachedto the wall, thus space is saved and the operator is kept away from the

Text Appearing After Image:

« Fig. 100.—Authoes Table and Tube-Holder.—The pulley moves the tube-holder to and fro.The Tentril tube is connected in series with the Crookes tube and lessens the reverse current, whosevacuum can be lowered, at pleasure, by the operator compressing-, at a distance from the tube, a bulb,which drives a blast of air into a gas flame, thus allowing the heating of the platinum in the ventriltube. magnetic field. The latter method is prevalent in Germany. The con-trolling apparatus (the interrupter, rheostat, switch-board, etc.) shouldbe within easy reach. After installing the coil, the source of current canbe connected with it by the use of the switch-board. The switch-boardis provided with several binding posts, the latter being connected with 196 ELECTEO-THEEAPEUTICS.

Nothing Found.

label_outline

Tags

rontgen rays and electro therapeutics 1910 book illustrations medicine medical illustrations medical history x ray rontgen electrotherapeutics high resolution images from internet archive
date_range

Date

1910
create

Source

Open Knowledge Commons and Harvard Medical School
link

Link

http://commons.wikimedia.org/
copyright

Copyright info

public domain

label_outline Explore Rontgen Rays And Electro Therapeutics 1910

Topics

rontgen rays and electro therapeutics 1910 book illustrations medicine medical illustrations medical history x ray rontgen electrotherapeutics high resolution images from internet archive