visibility Similar

code Related

Röntgen rays and electro-therapeutics - with chapters on radium and phototherapy (1910) (14571581848)

description

Summary

Identifier: rntgenrayselectr00kass (find matches)

Title: Röntgen rays and electro-therapeutics : with chapters on radium and phototherapy

Year: 1910 (1910s)

Authors: Kassabian, Mihran Krikor, 1870-1910

Subjects: Electrotherapeutics X-rays Phototherapy Radiology Radiotherapy

Publisher: Philadelphia & London : J.B. Lippincott Company

Contributing Library: Francis A. Countway Library of Medicine

Digitizing Sponsor: Open Knowledge Commons and Harvard Medical School

Text Appearing Before Image:

themeasurement is made of the shadow of the body above each of the balls,and should be followed, especially if the body is some distance away fromthe anterior segment of the globe or is in the orbit. If the foreign body has passed into the orbit, the rotation of theeyeball to insure parallelism of the ocular axis with the plane of theplate leads to a slight error in the determination of the position of the THE CLINICAL APPLICATIONS. 289 metal. To eliminate this error necessitates a knowledge of the angle ofthe orbit with the plate or, its equivalent, the amount of deviation ofthe eyeball from the primarj^ position, and the consideration of thisangle in plotting the diagrammatic circles representing the eyeball. The indicating apparatus is secured to the side of the head corre-sponding to the injured eye, and the tube jDlaced about 12 or 15 inches(30 or 38 cm.) to the opposite side and slightly forward. The patient isin the recumbent posture, to insure steadiness of the head. After the

Text Appearing After Image:

Fig. 170.—Mackenzie Davidsons localizer. indicating rods have been adjusted, the patient fixes an object about 5 to10 feet distant, so placed that the visual axis of the injured eye shall beparallel to the photographic plate. An exposure of from 10 to 20seconds will clearly outline the bones of the orbit, and secure a shadowof any body opaque to the rays in the eyeball or in its neighborhood. Another method of equal accuracy was introduced by MackenzieDavidson, who published a description of it in the British MedicalJournal^ January 1, 1896. Davidsons Metliod. (Fig. 170.)—The theory of this method briefly isas follows :^ The Crookes tube is placed in a holder, which can slidehorizontally. A perpendicular is dropped from the point in the anode of ^The Archives of the Kontgen Ray, May, li 19 290 ELECTEO-THERAPEUTICS. the tube where the X-rays originate on the point where two wires crosseach other at right angles, and one of the wires must be parallel to thehorizontal bar along which

label_outline

Tags

rontgen rays and electro therapeutics 1910 book illustrations medicine medical illustrations medical history x ray röntgen electrotherapeutics images from internet archive
date_range

Date

1910
create

Source

Open Knowledge Commons and Harvard Medical School
link

Link

http://commons.wikimedia.org/
copyright

Copyright info

public domain

label_outline Explore Rontgen Rays And Electro Therapeutics 1910

Topics

rontgen rays and electro therapeutics 1910 book illustrations medicine medical illustrations medical history x ray röntgen electrotherapeutics images from internet archive