Diese Seite ist nicht vollständig übersetzt. Klicken Sie auf die Schaltfläche Übersetzen, um die neueste übersetzte Version zu laden.

visibility Similar

code Related

A manual of practical medical electricity - the Röntgen rays and Finsen light (1902) (14783703025)

description

Zusammenfassung

Identifier: manualofpractica00turn (find matches)

Title: A manual of practical medical electricity : the Röntgen rays and Finsen light

Year: 1902 (1900s)

Authors: Turner, Dawson

Subjects: X-Rays Electrophysiology Electrosurgery Electric Stimulation Therapy Electrotherapeutics X-rays Electrophysiology Electrosurgery

Publisher: New York : William Wood & Company

Contributing Library: Francis A. Countway Library of Medicine

Digitizing Sponsor: Open Knowledge Commons and Harvard Medical School

Text Appearing Before Image:

Fig. 125.—Apostolis Electrodes. also serve the purpose ; it is cleanly, easily managed, andclings closely to the body. A uterine sound electrode. The exposed end shouldbe about half an inch to one inch in length, and made of Electro-Surgery 253 platinum, gold, or carbon ; the stem may be made ofcopper, carefully insulated by vulcanite. Apostoli nowuses gas carbon electrodes ; a metallic stem, insulated bycaoutchouc, bears a screw at one extremity, to which rodsof gas carbon, all one inch in length, but of differentdiameters, can be attached. The caoutchouc coveringis marked with grooves at regular distances of one inch(Fig. 123).For galvano-puncture a sharp-pointed steel trocar sliding

Text Appearing After Image:

Fig. 126.—Arrangement of Apparatus for the ApostoliTreatment. in an insulating sheath of celluloid. If the positive polebe used to puncture with, the needle should be of gold(Fig. 125). Preparation of the Apparatus. Connect the rheophore coming from the positive pole ofthe battery to one of the binding screws of the rheostat,and a wire passing to the galvanometer to the other(Fig. 126) ; let them be on a firm table ; then attach along wire intended to reach the uterine sound to the otherterminal of the galvanometer. Let the rheostat be screwedout to its full distance. Attach the other rheophore to the 254 A Manual of Practical Medical Electricity negative pole of the battery. Turn on all the cells, andplunge the ends of both terminal wires into a vessel ofwater, taking great care not to allow them to touch. Gasshould now be pretty freely given off, and in much largerquantity from the negative terminal. This decides twoquestions—whether all the cells are properly connectedand in wo

label_outline

Tags

ein Handbuch der praktischen medizinischen Elektrizität Buchillustrationen Medizin medizinische Illustrationen Krankengeschichte Geschichte der Technologie elektrische Energie Elektrizität Röntgen röntgen Operation medizinische Therapie Elektrotherapeutika Bilder aus dem Internetarchiv
date_range

Datum

1902
create

Quelle

Open Knowledge Commons and Harvard Medical School
link

Link

http://commons.wikimedia.org/
copyright

Copyright-info

public domain

label_outline Explore A Manual Of Practical Medical Electricity

Themen

ein Handbuch der praktischen medizinischen Elektrizität Buchillustrationen Medizin medizinische Illustrationen Krankengeschichte Geschichte der Technologie elektrische Energie Elektrizität Röntgen röntgen Operation medizinische Therapie Elektrotherapeutika Bilder aus dem Internetarchiv