Diese Seite ist nicht vollständig übersetzt. Klicken Sie auf die Schaltfläche Übersetzen, um die neueste übersetzte Version zu laden.

visibility Similar

code Related

A manual of practical medical electricity - the Röntgen rays and Finsen light (1902) (14803526923)

description

Zusammenfassung

Identifier: manualofpractica00turn (find matches)

Title: A manual of practical medical electricity : the Röntgen rays and Finsen light

Year: 1902 (1900s)

Authors: Turner, Dawson

Subjects: X-Rays Electrophysiology Electrosurgery Electric Stimulation Therapy Electrotherapeutics X-rays Electrophysiology Electrosurgery

Publisher: New York : William Wood & Company

Contributing Library: Francis A. Countway Library of Medicine

Digitizing Sponsor: Open Knowledge Commons and Harvard Medical School

Text Appearing Before Image:

Faradic Electricity 117 position in which the latter may be (the distance from theprimary coil) may be accurately noted. A bundle of soft iron wires covered with an insulatingvarnish, and enclosed in a light case, which is graduated,can be placed within or withdrawn to any required degree,according to the graduations, from the primary coil. Thisforms an electro-magnet, which is more rapidly magnetiz-able and demagnetizable than a solid one would be,because the induction currents, which would be set incirculation in a solid rod, are partly eliminated. The primary coil is wound with a few turns of thickwire to diminish resistance and self-induction. The secondary coil is wound with very many turns of

Text Appearing After Image:

TSScc. Prim. J,+ Fig. 70.—Diagram of Induction Coil from Above. thin wire, which must be most carefully insulated fromeach other to prevent the high electromotive forceliberated from short-circuiting. The greater the numberof the coils, the greater the mutual induction and electro-motive force. The increased resistance may, therefore,be disregarded. To open and close the primary circuit with rapidity, amechanical arrangement, known as Neefs hammer, isemployed (Fig. 69). When a current is passed throughthe electro-magnet B, it attracts to it the movable arma-ture C, which at other times is kept in contact with theplatinum-faced screw A by the spring D. If the circuit be closed in such an arrangement, thecurrent, entering by the pillar E, will flow through the ii8 A Manual of Practical Medical Electricity armature C, and along screw A into the primary coil,returning round the electro-magnet B, which thereforebecomes magnetized, and attracts the armature C, break-ing its contact with A

label_outline

Tags

ein Handbuch der praktischen medizinischen Elektrizität Buchillustrationen Medizin medizinische Illustrationen Krankengeschichte Geschichte der Technologie elektrische Energie Elektrizität Röntgen röntgen medizinische Therapie Elektrotherapeutika Bilder aus dem Internetarchiv
date_range

Datum

1902
create

Quelle

Open Knowledge Commons and Harvard Medical School
link

Link

http://commons.wikimedia.org/
copyright

Copyright-info

public domain

label_outline Explore A Manual Of Practical Medical Electricity

Themen

ein Handbuch der praktischen medizinischen Elektrizität Buchillustrationen Medizin medizinische Illustrationen Krankengeschichte Geschichte der Technologie elektrische Energie Elektrizität Röntgen röntgen medizinische Therapie Elektrotherapeutika Bilder aus dem Internetarchiv